Plate Heat Exchangers

Gasketed Plate Heat Exchanger

Approx Price: Rs 25,000 / Piece 
Minimum Order Quantity: 1 Piece
Product Details:
  • Plate Heat Exchanger Type: Gasketed Plate and Frame
  • Max Output Flow rate (m3/hr): 10-20, 30-40, 40-50, 50-100
  • Application: Heater, Cooler, Condenser
  • Type: Plate, Heat Recovery
  • Primary Exchanger Material: Steel
  • Brand: VARALKA
  • Orientation: Horizontal

Gasketed Plate Type Heat Exchangers

These industry mandate that PHEs must be all SS or SS clad to ensure sanitary and hygiene.

 

Some applications are: 

  • Cooling and Heating of Milk and Milk Products

  • Heating / Cooling of Sugar Syrup and Juices

  • Cooling and Heating of Vegetable Oil

  • Wort Cooling and Heating


Product Program
Connections Sizes
: DN15 to DN550
Flow Rates: <6000 m3/hour
Working Pressure: < 25 Bar
Working Temperature
: 180 deg C (240 deg C for some models)



Plate Materials
: SS304/I316L, Ti. Gr 1, Ti Gr 11, Hastelloy C-276, Ni-201
Gasket Materials: NBR, EPDM, FKM, CR, HNBR, PTFE Encapsulated Elastomers
Frame Materials: IS2062, SA516 Gr 60/70, SS304, SS304 Cladded
Tie-Rods, Fasteners: IS1367, SA193/SA194, ASTM A193/194



Construction Codes: Standard Engineering Practice, ASME Sec VIII Div 1, U Stamp(*)

Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)

Double Wall Plate Type Heat Exchanger

Approx Price: Rs 45,000 / Piece 
Minimum Order Quantity: 1 Piece
Product Details:
  • Plate Heat Exchanger Type: Gasketed Plate and Frame
  • Max Output Flow rate (m3/hr): 50-100
  • Application: Heater, Cooler
  • Primary Exchanger Material: Steel
  • Brand: VARALKA
  • Medium Used: Water

Double Wall Plate Type Heat Exchanger

Double Wall PHEs are a compact solution to conventionally used double wall shell and tubes and double coils. 

 

The double plates offer maximum safety against intermixing of the two fluids in the plate type heat exchanger. The double plates are constructed by laser welding 2 identical plates around the ports. Thin air gap between the plates ensures that if any one of the two fluids would leak through the first plate it would leak to atmosphere and would be visible outside.

Some Applications of Double Wall PHEs are:

 

Transformer Oil Cooling
Water contamination in transformer oil can result in severe damage to the transformer and can result in plant shutdowns.

Lube Oil Cooling
Oil mixing with the cooling medium (sea, lake, river or cooling tower water), can cause severe damage to the environment. Also, if the cooling medium mixes with the oil, serious damage can be caused to the equipment being cooled.

Quench Oil Cooling
Water mixing with quench oil can cause a steam explosion.

Chemical Processes
Intermixing of process media can create accelerated corrosion, an explosion, undesirable chemical reactions or contamination.

 

Example:  Accelerated corrosion results in chlorated hydrocarbons intermix with water to produce hydrochloric acid.

Food and Pharma Processes
Product intermixing with the other media may contaminate final product. 

 


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
Looking for Plate Heat Exchangers ?
Share Us:
© Abhishek Engineering Group
Desktop Site Back to top